Sale!

WST IV ZH2 Combination Linear Tap Changer (Y-Δ Switching)

Sophisticated ZH2 Combination linear switch designed for Star-Delta (Y-Δ) connection switching and centralized voltage adjustment in specialized transformers.

OEM and Small Qty and Fast Delivery

“Tell us your requirement, we will reply within 12 hours”

The WST IV series offers a dual-function ZH2 design, enabling both Y-Delta connection transitions and centralized voltage adjustment. This makes it an essential component for specialized multi-configuration transformers requiring high operational flexibility and mechanical durability.

WST-IV-ZH2-Y-Delta-switching-linear-tap-changer-layout

 

Technical Principles & Notice

  • Voltage Regulation: Adjusts the high-voltage winding turns ratio to stabilize output voltage.

  • Loss Minimization: Optimized contact design reduces power losses. Since voltage loss is inversely proportional to the voltage level, our switches ensure peak transmission efficiency.

  • Compatibility: Fully compatible with Mineral Transformer Oil and Silicon Oil.

WST-IV-ZH2-Y-Delta-switching-linear-tap-changer-layout

“Please select the corresponding Model No. (1-15) from the dropdown list according to the dimension table above.”

Technical Table

ParameterSpecification
Regulation TypeOff-Circuit (Manual, De-energized)
Rated Voltage10kV -35kV
Rated Current63A -250A
Positions3-5 Positions
Regulation Step2.5% per position

 

📘 Frequently Asked Questions (FAQs)

  1. Q: How do I choose between WST I and WST III?

    • A: WST I is for Terminal Point regulation, while WST III is for Neutral Point regulation. Check your transformer winding diagram before ordering.

  2. Q: Why do WST II, IV, and V have two operating handles?

    • A: These are “Combination Types” (ZH2/ZH3). The dual handles are required to perform complex tasks like Y-Delta switching or Series-Parallel transitions.

  3. Q: Can I operate the WST tap changer while the transformer is powered?

    • A: NO. This is an Off-Circuit device. Switching must only be performed when the transformer is completely de-energized.

  4. Q: What is the significance of the “T” suffix in model numbers?

    • A: The “T” indicates a specialized design with modified dimensions or terminal points. Please contact us for specific drawings.

  5. Q: What is the standard regulation step?

    • A: The standard regulation is 2.5% per position, allowing for precise voltage control across 3 to 9 steps.

⚠️ Safety Operation (Mandatory)

This is an OFF-CIRCUIT device. Switching must ONLY be performed when the transformer is completely DE-ENERGIZED and isolated from the grid. Manual operation during energized states is strictly prohibited and will cause catastrophic equipment failure.

📍 Important Procurement Notice

  • Please cross-check the Total Length (L) and Mounting Height (H) in the dimension table against your internal tank clearance.

  • Refer to the serial number (1-15/23) in the datasheet to select the exact model from the dropdown menu.

You may also like…